text.skipToContent text.skipToNavigation

Call us at 1-888-826-6342

Call us at 1-888-826-6342

Back To Top

DIN Rail Signal Conditioners

45 Products
Non Isolated Loop Powered DIN Rail RTD Input Conditioner

The DRSL-RTD-LP is a 2, 3, or 4-wire PT100 RTD input conditioner. Output loop powered with high accuracy and slim housing. Pre-calibrated temp range DIP switch selected.

View Specs
DIN Rail DC Current Signal Splitters w/ Dual Output

The DRSP-I Series are DC current splitters that take one 4-20mA input to two 4-20mA outputs w/ AC or DC power. Zero and span adjustments for each output, status LEDs.

View Specs
DIN Rail Input Loop Powered Isolators w/ 1 or 2 Channel Models

The DRSL-LPI Series Conditioners are 1 or 2 channel analog input loop powered isolators. 1:1 signal ratio, low input voltage drop, slim housing.

View Specs
DIN Rail Field Configurable Alarm Limit Modules

The DRG-AR Series Conditioners are TC, RTC, DC or AC voltage and current input with 2 SPDT Relay Outputs. Field configurable ranges with adjustable setpoints.

View Specs
DIN Rail Isolated Repeater/Splitter for Process Signals.

The DRSL-SP2 is a repeater/splitter that isolates and converts 1 process input to 2 process outputs. DIP switch selectable ranges. Slim housing, high accuracy (0.05%)

View Specs
DIN Rail Temperature Loop Powered Signal Conditioner

The DRSL-TEMP is an output loop powered temperature signal conditioner. Accepts Type J, Type K, or 2, 3 or 4 wire Pt100 RTD input. Slim housing, high accuracy.

View Specs
DIN Rail Strain Gage/Load Cell Transmitter w/ Bipolar mA/V Output

TXDIN1600S strain gage/load cell transmitter accepts 0.2 to 7.5 mV/V inputs with 5V excitation. Universal current, bipolar voltage output. Remote tare, front panel config.

View Specs
DIN Rail Universal Input Transmitter with Push Button User Trim

TXDIN1600 series has a universal thermocouple, RTD, or process input and 4-20mA output. Configuration via USB cable (sold separately). Push button user trim, relay output

View Specs
DIN Rail Universal Smart Transmitter w/ LED Display

TXDIN101 has thermocouple, RTD, and mV input with 4-20mA output. LED display, configuration TX69-CABLE sold separately required to program via PC.

View Specs
DIN RAIL Signal Conditioner for Load Cells

The DRST-BG is a load cell & strain gage amplifier that converts mV to current or voltage. Front panel programmable LED display | Calibration of input span, external taring.

View Specs
DIN Rail Isolated Repeater/Splitter for Bipolar Process Signals

The DRSL-SP3 is a repeater/splitter that isolates and converts 1 bipolar process input to 2 process outputs. DIP switch selectable ranges, slim housing, high accuracy.

View Specs
DIN Rail Load Cell Input Signal Conditioner

The DRF-LC Series Conditioners are load cell input with 0-10V or 4-20mA output. For load cells with 1, 2, or 3 mV/V output. Full scale at 10, 20, or 30mV. Pre-tare jumpers

View Specs
DIN Rail Signal Conditioner Series with Process Input

The DRSL-DC1-DC2 Conditioners have a DC current and voltage input and isolated and converted DC current and voltage output. DIP switch selectable range. 0.2% accuracy

View Specs
DIN Rail Isolated Repeater/Splitter for Current Signals

The DRSL-SP1 is a repeater/splitter that isolates and converts 1 current input to 2 current outputs. Slim housing, high accuracy (0.05%), no setup needed.

View Specs
DIN Rail AC Current and Voltage Transmitter

The DRST-AC measures AC current or voltage signals and outputs passive or active current signals. UL and c-UL approved. Universal power. Programmer required.

View Specs
DIN Rail Signal Conditioner for AC LVDT Transducers

The LDX-D is a DIN rail mount AC LVDT transducer that operates on 10-30Vdc power with selectable process outputs. Adjustable signal polarity, span, and offset.

View Specs
Snap In Front Panel Programmer with Modbus over RS-485

The DRST-CM is a programming display for DRST-AC, DRST-DC, DRST-UN & DRST-UR. Supports Modbus over RS-485. Monitors process value on built in display.

View Specs
DIN Rail Conditioners Convert Voltage or Bridge Input to RS-485

DIN-100 Conditioners convert analog signals to RS-485 to a PC or other processor based equipment. Input types are temperature, bridge, V or mA, D I/O. NV memory storage.

View Specs
DIN Rail Output Loop Powered Isolators w/ 1 or 2 Channel Models

The DRSL-LPO Series Conditioners are 1 or 2 channel output loop powered 2 wire isolators. 1:1 signal ratio, low voltage drop, slim housing. 0.05% accuracy.

View Specs
DIN Rail Transmitter with RFID Communications

TXDIN400 series transmitters accept thermocouple or RTD input (TX401) or process voltage, current, or resistance (TX402). Configurable via RFID with TX400-RFID accessory.

View Specs

DIN Rail Signal Conditioners

Omega offers a wide variety of DIN Rail mounted signal conditioners. Choose based on input type or based on sensor type and output voltage. We have hundreds of options to choose from!
Searching for your items
en-US
en
Save Configuration