Switch OperationApprox. half the distance from the end of stem to mounting or halfway point of float travel in liquid of 1.0 specific gravity.
Switch typeSPST
These liquid level switches are sealed with potting compound. The only path for liquid to the electrical switch would be through the wires. If the wires are terminated in an appropriate manner (eg. –NEMA-6 connectors), the level switch will meet or exceed a NEMA-6 rating, making them suitable for submersion with years of worry free operation in moisture-laden environments. A sealed SPST switch provides consistent accuracy and high repeatability with the effects of shock, vacuum or vibration minimized. The switch is extremely versatile since it is user selectable as a normally open or normally closed by simply reversing the float or the mounting of the switch. The standard NPT male fittings allow for quick installation in either the top or bottom of the tank or vessel.
Rated 5 out of
5 by
Anonymous from
Great product for high temp passivation baths!Heavy Duty! Using it for our acidic passivation tanks that are heated! No issues so far!
I was reading the specifications of the level switch model LVN-40, I see that the length of the cable is 24”. Is there a possibility to order a longer cable?
Asked by: Anonymous
Thank you for your inquiry! Unfortunately, these level switches are not offered with longer lead wire lengths
Answered by: Application Engineer JM
Date published: 2022-08-04
Can this sensor be connected to alarm or horn or LED light?
Asked by: Amin
Thank you for your inquiry! Yes, the level switch can be used to activate indicators like lights or horns.