The LVSW-701 Series solid state liquid level switch is a direct replacement for mechanical float-type liquid level devices. The switch employs proven ultrasonic technology and solid state integral electronics, and provides reliable operation in virtually any liquid, regardless of viscosity. This eliminates problems of stickiness and failure rate due to finite mechanical life inherent in the mechanical float design. The combination of fully epoxy-sealed electronics and ultrasonic sensing technology will provide years of maintenance free service.
Specifications Repeatability: 2 mm (0.08") or better Delay: 0.5 sec Input Power: 6 to 24 Vdc Leakage Current: Less than 50 uA Outputs: Relay Output: 1 A SPDT relay Protection: Transient, reverse polarity Sensor: 316 LSS Temperature: -29 to 71°C (-20 to 160°F) Pressure: 316 SS Models: Up to 1000 psig (6895 kPa) Mounting: ¾ NPT standard
Is this the best replacement for the discontinued LV751-DC radio frequency level detector?
Asked by: Certified
Thank you for your question?
The only DC powered radio frequency level switch we have is the LVCN7212. The connection size for this sensor is ¾” and the maximum pressure this sensor can handle is 145PSI. Please review the specs for the LVCN7212 and ensure it will work for your application
Answered by: application engineer je
Date published: 2019-07-03
Do you have this or a similar item that is NSF61 rated?
Asked by: jerome
Thank you for your inquiry on this product. Unfortunately, no.
Answered by: Application Engineer JC
Date published: 2020-07-11
what is the length of the cord.
Asked by: EdPa
Thank you for your inquiry about the level switch. The cable length is 12 inches and unfortunately, cannot be customized for longer lengths.
Answered by: Application Engineer JC
Date published: 2022-06-09
For the LVSW-701 Ultrasonic Liquid Level Switch
I need the RoHS and the EMC Declaration of Conformity
If the Low Voltage Directive (LVD) applies I nedd it also.
Asked by: glb4
Thank you for your inquiry about the level switch. Please direct your inquiry to our Customer Care Group and a representative can a copy of the Declaration of Conformity in a separate email. Also, the level switch is not RoHS Compliant as indicated on its data sheet.