The LVU800 Series general purpose 2-wire ultrasonic transmitter provides non-contact level measurement up to 10 m (32'), and is ideally suited for challenging ultrapure, corrosive or waste liquids. Pushbutton calibrated, the transmitter is broadly selected for atmospheric bulk storage, day tank and waste sump applications. Media examples include wastewater and sodium hydroxide.
SPECIFICATIONS Range: LVU809: 10 cm to 3 m (4" to 9.8') LVU816: 20 cm to 5.5 m(8" to 18') LVU826: 20 cm to 8 m(8" to 26.2') LVU832: 30 cm to 10 m(12" to 32.8') Accuracy: ±0.2% of span Resolution: LVU809: 0.5 mm (0.019") LVU816/826: 1 mm (0.039") LVU832: 2 mm (0.078") Beam Width: LVU809: 5 cm (2") dia. LVU816/LVU826/LVU832: 7.6 cm (3") dia. Deadband: LVU809: 10 cm (4") LVU816: 20 cm (8") LVU826: 20 cm (8") LVU832: 30 cm (12") Display Type: LCD, 6-digit Display Units: Inch, cm or percent Display Mode: Air gap or liquid height Memory: Non-volatile Supply Voltage: 12 to 28 Vdc Loop Resistance: 500 O @ 24 Vdc Signal Output: 4 to 20 mA, 2-wire Signal Invert: 4 to 20 mA or 20 to 4 mA Calibration: Push button Fail-Safety: Selectable 4 mA, 20 mA, 21 mA, 22 mA or hold Process Temperature: -20 to 60°C (-7 to 140°F) Temperature Compensation: Automatic Electronics Temperature:n -40 to 71°C (-40 to 160°F) Pressure: 30 psi (2 bar) @ 25°C, derated @ 1.667 psi (0.113 bar) per above 25°C Enclosure Rating: NEMA 4X (IP65) Enclosure Vent: Watertight membrane Enclosure Material: PC/ABS FR Transducer Material: PVDF Process Mount: LVU809: 1 NPT or 1"G LVU816/LVU826/LVU832: 2 NPT or 2" G Mounting Gasket: FKM Conduit Entrance: Dual, 1/2 NPT Classification: General purpose CE compliance EN 61326 EMC
Rated 4 out of
5 by
Ronald Smith from
Great little unitSmall footprint, easy to program, accurate, dependable
Date published: 2016-10-06
Rated 5 out of
5 by
Mike K from
Great Level TransmitterExcellent instrument for a modest cost.
Easy to setup
Good repeatability.
Date published: 2021-09-29
Rated 4 out of
5 by
wolfebrand from
Simple, dependable level transmitterWe have been using these Omega Level sensors for more than 10 years now. I like them because they are simple to use and install, work well for our application, they tend to be pretty dependable as well as accurate, to within about 1/4" the best I can tell.
We use them to monitor liquid chlorine bleach (Sodium Hypochlorite) in a 1,100 and 2,000 gallon plastic tanks.
Date published: 2021-02-01
Rated 5 out of
5 by
Anonymous from
V-notch weir measurementWe use this to measure the depth of water for a v-notch weir on a Fluid Metering experiment in Chemical Engineering. The V-notch weir is an ancient way of measuring water and is taught to show the evolution of water measurement. The original one I bought from Omega had a loose wire from 8 years of use and the measurements made no sense. I bought this model again as it works great for our needs.
you · a few seconds ago
we want to purchase level transmitter for use on caustic closed tank and HNO3 Closed tanks. please suggest us the model which is compatible to these liquids. range of tanks are upto 5meters.
Asked by: abdul latid
Thank you for your interest in this product. Please email flow@omega.com and will address it with additional questions required.