Thermocouples with mounted inside a stainless steel washer housing. Easily bolt to a variety of surfaces to measure temperature. Available in type J, K, T, or E calibrations.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Cable Insulation | Termination Connection Type | Cable Length | Color Code Standard | Additional Features | Mounting Style | Probe Diameter | Minimum Temperature Measurement | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
E
|
0 to 482°C (32 to 900°F)
|
Bolt-On
|
Fiberglass
|
Stripped Leads
|
12 in
|
ANSI (Standard)
|
#6 Screw Size
|
#6 Screw Size
|
# 6 or M3.5 Screw
|
12 in
|
Not Applicable
|
|
Thermocouple
|
E
|
0 to 482°C (32 to 900°F)
|
Bolt-On
|
Fiberglass
|
Stripped Leads
|
24 in
|
ANSI (Standard)
|
#6 Screw Size
|
#6 Screw Size
|
# 6 or M3.5 Screw
|
24 in
|
Not Applicable
|
|
Thermocouple
|
E
|
0 to 482°C (32 to 900°F)
|
Bolt-On
|
Fiberglass
|
Stripped Leads
|
36 in
|
ANSI (Standard)
|
#6 Screw Size
|
#6 Screw Size
|
# 6 or M3.5 Screw
|
36 in
|
Not Applicable
|
|
Thermocouple
|
E
|
0 to 482°C (32 to 900°F)
|
Bolt-On
|
Fiberglass
|
Stripped Leads
|
60 in
|
ANSI (Standard)
|
#6 Screw Size
|
#6 Screw Size
|
# 6 or M3.5 Screw
|
60 in
|
Not Applicable
|
|
Thermocouple
|
E
|
0 to 482°C (32 to 900°F)
|
Bolt-On
|
Fiberglass
|
Stripped Leads
|
12 in
|
ANSI (Standard)
|
#8 Screw Size
|
#8 Screw Size
|
#8 or M4 Screw
|
12 in
|
Not Applicable
|
General use fast response thermocouples mounted in glass tape & polyimide with a self-adhesive backing for easily measuring surface temperatures up to 175°C. IEC color-coded.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Cable Insulation | Termination Connection Type | Cable Length | Color Code Standard | Mounting Style | Probe Diameter | Minimum Temperature Measurement | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
E
|
0 to 175°C (32 to 350°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
1 m
|
IEC
|
Standard
|
Not Applicable
|
1 Meter
|
Not Applicable
|
|
Thermocouple
|
E
|
0 to 175°C (32 to 350°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
2 m
|
IEC
|
Standard
|
Not Applicable
|
2 Meter
|
Not Applicable
|
|
Thermocouple
|
J
|
0 to 175°C (32 to 350°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
1 m
|
IEC
|
Standard
|
Not Applicable
|
1 Meter
|
Not Applicable
|
|
Thermocouple
|
J
|
0 to 175°C (32 to 350°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
2 m
|
IEC
|
Standard
|
Not Applicable
|
2 Meter
|
Not Applicable
|
|
Thermocouple
|
K
|
0 to 175°C (32 to 350°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
1 m
|
IEC
|
Standard
|
Not Applicable
|
1 Meter
|
Not Applicable
|
The SAP series thermocouple sensors come in curved and flat styles. An adhesive pad holds the sensor onto the measuring surface. These come in types J, K, T and E.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Cable Insulation | Termination Connection Type | Cable Length | Color Code Standard | Mounting Style | Features |
---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
E
|
-50 to 200°C (-58 to 392°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
36 in
|
ANSI (Standard)
|
Curved Surface Mounting
|
Thin backing for fast response
|
|
Thermocouple
|
E
|
-50 to 200°C (-58 to 392°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
72 in
|
ANSI (Standard)
|
Curved Surface Mounting
|
Thin backing for fast response
|
|
Thermocouple
|
J
|
-50 to 200°C (-58 to 392°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
36 in
|
ANSI (Standard)
|
Curved Surface Mounting
|
Thin backing for fast response
|
|
Thermocouple
|
J
|
-50 to 200°C (-58 to 392°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
72 in
|
ANSI (Standard)
|
Curved Surface Mounting
|
Thin backing for fast response
|
|
Thermocouple
|
K
|
-50 to 200°C (-58 to 392°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
36 in
|
ANSI (Standard)
|
Curved Surface Mounting
|
Thin backing for fast response
|
Fast response thermocouples mounted in a polyimide carrier with a self-adhesive backing for easily measuring surface temperatures up to 260°C. Resistant to oil and chemicals.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Cable Insulation | Termination Connection Type | Cable Length | Color Code Standard | Probe Diameter | Minimum Temperature Measurement | Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
J
|
-17 to 260°C (0 to 500°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
40 in
|
ANSI (Standard)
|
Not Applicable
|
40 in
|
Not Applicable
|
|
Thermocouple
|
K
|
-17 to 260°C (0 to 500°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
40 in
|
ANSI (Standard)
|
Not Applicable
|
36 in
|
Not Applicable
|
|
Thermocouple
|
T
|
-17 to 150°C (0 to 302°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
40 in
|
ANSI (Standard)
|
Not Applicable
|
40 in
|
Not Applicable
|
|
Thermocouple
|
J
|
-17 to 260°C (0 to 500°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
1 m
|
IEC
|
Not Applicable
|
40 in
|
IEC Color Code
|
|
Thermocouple
|
K
|
-17 to 260°C (0 to 500°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
1 m
|
IEC
|
Not Applicable
|
40 in
|
Not Applicable
|
Thin film thermocouples with extremely fast response times that can be glued, epoxied, or cemented onto surfaces for short or long-term temperature measurement.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Cable Insulation | Termination Connection Type | Cable Length | Color Code Standard | Mounting Style | Probe Diameter | Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
E
|
0 to 260°C (32 to 500°F)
|
Cement-On
|
Fiberglass
|
Stripped Leads
|
40 in
|
ANSI (Standard)
|
Cement-On
|
Not Applicable
|
Style 1, Butt Weld
|
|
Thermocouple
|
K
|
0 to 260°C (32 to 500°F)
|
Cement-On
|
Fiberglass
|
Stripped Leads
|
40 in
|
ANSI (Standard)
|
Cement-On
|
Not Applicable
|
Style 1, Butt Weld
|
|
Thermocouple
|
T
|
0 to 150°C (32 to 300°F)
|
Cement-On
|
Fiberglass
|
Stripped Leads
|
40 in
|
ANSI (Standard)
|
Cement-On
|
Not Applicable
|
Style 1, Butt Weld
|
|
Thermocouple
|
E
|
0 to 425°C (32 to 800°F)
|
Cement-On
|
Thermocouple Alloy
|
Stripped Leads
|
6 in
|
ANSI (Standard)
|
Cement-On
|
Not Applicable
|
Style 2, Butt Weld
|
|
Thermocouple
|
K
|
0 to 540°C (32 to 1000°F)
|
Cement-On
|
Thermocouple Alloy
|
Stripped Leads
|
6 in
|
ANSI (Standard)
|
Cement-On
|
Not Applicable
|
Style 2, Butt Weld
|
Fast response thermocouples mounted in glass tape & polyimide with a self-adhesive backing and fiberglass lead-wires for easily measuring surface temperatures up to 315°C.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Cable Insulation | Termination Connection Type | Cable Length | Color Code Standard | Mounting Style | Probe Diameter | Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
E
|
0 to 315°C (32 to 600°F)
|
Surface
|
Fiberglass
|
Stripped Leads
|
40 in
|
ANSI (standard)
|
Standard
|
Not Applicable
|
Not Applicable
|
|
Thermocouple
|
J
|
0 to 315°C (32 to 600°F)
|
Surface
|
Fiberglass
|
Stripped Leads
|
40 in
|
ANSI (standard)
|
Standard
|
Not Applicable
|
Not Applicable
|
|
Thermocouple
|
K
|
0 to 315°C (32 to 600°F)
|
Surface
|
Fiberglass
|
Stripped Leads
|
40 in
|
ANSI (standard)
|
Standard
|
Not Applicable
|
Not Applicable
|
|
Thermocouple
|
T
|
0 to 150°C (32 to 302°F)
|
Surface
|
Fiberglass
|
Stripped Leads
|
40 in
|
ANSI (standard)
|
Standard
|
Not Applicable
|
Not Applicable
|
|
Thermocouple
|
J
|
0 to 315°C (32 to 600°F)
|
Surface
|
Fiberglass
|
Stripped Leads
|
1 m
|
IEC
|
Standard
|
Not Applicable
|
IEC standard
|
General use fast response thermocouples mounted in glass tape & polyimide with a self-adhesive backing for easily measuring surface temperatures up to 175°C.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Cable Insulation | Termination Connection Type | Cable Length | Color Code Standard | Mounting Style | Probe Diameter | Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
E
|
0 to 175°C (32 to 350°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
40 in
|
ANSI (Standard)
|
Standard
|
Not Applicable
|
Not Applicable
|
|
Thermocouple
|
J
|
0 to 175°C (32 to 350°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
40 in
|
ANSI (Standard)
|
Standard
|
Not Applicable
|
Not Applicable
|
|
Thermocouple
|
K
|
0 to 175°C (32 to 350°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
40 in
|
ANSI (Standard)
|
Standard
|
Not Applicable
|
Not Applicable
|
|
Thermocouple
|
T
|
0 to 150°C (32 to 302°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
40 in
|
ANSI (Standard)
|
Standard
|
Not Applicable
|
Not Applicable
|
|
Thermocouple
|
E
|
0 to 175°C (32 to 350°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
80 in
|
ANSI (Standard)
|
Standard
|
Not Applicable
|
Not Applicable
|
General use fast response RTDs mounted in glass tape & polyimide with a self-adhesive backing for easily measuring surface temperatures up to 290°C. Class A Accuracy.
Product Number | Category | Process Temperature Range | Sensor Application | Nominal Resistance | Accuracy | Number of Wires | Cable Insulation | Termination Connection Type | Cable Length | Mounting Style | Maximum Temperature Measurement | Minimum Temperature Measurement |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RTD
|
-73°C to 260°C (-100°F to 500°F)
|
Self-Adhesive
|
100 Ω
|
±0.15°C
|
3
|
PFA
|
Stripped Leads
|
40 in
|
Class A DIN Platinum
|
260°C (500°F)
|
-73°C
|
|
RTD
|
-73°C to 260°C (-100°F to 500°F)
|
Self-Adhesive
|
100 Ω
|
±0.15°C
|
4
|
PFA
|
Stripped Leads
|
40 in
|
Class A DIN Platinum
|
260°C (500°F)
|
-73°C
|
|
RTD
|
-73°C to 260°C (-100°F to 500°F)
|
Self-Adhesive
|
100 Ω
|
±0.15°C
|
3
|
PFA
|
Stripped Leads
|
80 in
|
Class A DIN Platinum
|
260°C (500°F)
|
-73°C
|
|
RTD
|
-73°C to 260°C (-100°F to 500°F)
|
Self-Adhesive
|
100 Ω
|
±0.15°C
|
3
|
PFA with Stainless Steel Overbraid
|
Stripped Leads
|
40 in
|
Class A DIN Platinum
|
260°C (500°F)
|
-73°C
|
|
RTD
|
-73°C to 260°C (-100°F to 500°F)
|
Self-Adhesive
|
100 Ω
|
±0.15°C
|
3
|
PFA
|
Stripped Leads
|
120 in
|
Class A DIN Platinum
|
260°C (500°F)
|
-73°C
|
High-temperature abrasion resistant thermocouples with Inconel Overbraiding for measuring temperatures up to 1038°C in rugged applications like profiling ovens and furnaces.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Cable Insulation | Termination Connection Type | Cable Length | Color Code Standard | Mounting Style | Probe Diameter | Overbraiding and Fitting | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
E
|
0 to 540°C (32 to 1000°F)
|
Bolt-On
|
Nextel with Inconel Overbraid
|
Ceramic Beaded Leads with Spade Lugs
|
96 in
|
ANSI (Standard)
|
Ceramic Beaded leads
|
# 6 or M3.5 Screw
|
Inconel® 600
|
Bolted to surface
|
|
Thermocouple
|
E
|
0 to 540°C (32 to 1000°F)
|
Bolt-On
|
Nextel with Inconel Overbraid
|
Standard Connector
|
96 in
|
ANSI (Standard)
|
Not Applicable
|
# 6 or M3.5 Screw
|
Inconel® 600
|
Not Applicable
|
|
Thermocouple
|
E
|
0 to 540°C (32 to 1000°F)
|
Bolt-On
|
Nextel with Inconel Overbraid
|
Ceramic Standard Connector
|
96 in
|
ANSI (Standard)
|
Not Applicable
|
# 6 or M3.5 Screw
|
Inconel® 600
|
Not Applicable
|
|
Thermocouple
|
E
|
0 to 540°C (32 to 1000°F)
|
Bolt-On
|
Nextel with Inconel Overbraid
|
Spade Lugs
|
96 in
|
ANSI (Standard)
|
Not Applicable
|
# 6 or M3.5 Screw
|
Inconel® 600
|
Not Applicable
|
|
Thermocouple
|
E
|
0 to 540°C (32 to 1000°F)
|
Bolt-On
|
Nextel with Inconel Overbraid
|
Stripped Leads
|
96 in
|
ANSI (Standard)
|
Not Applicable
|
# 6 or M3.5 Screw
|
Inconel® 600
|
Not Applicable
|
General use thermocouples molded into silicone rubber with self-adhesive backing for easily measuring the temperatures of curved or flat surfaces up to 200°C.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Cable Insulation | Termination Connection Type | Cable Length | Color Code Standard | Additional Features | Mounting Style | Probe Diameter | Probe Length | Minimum Temperature Measurement | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
K
|
-50 to 200°C (-58 to 392°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
40 in
|
ANSI (Standard)
|
Curved Surface Mounting
|
Curved Surface Mounting
|
Not Applicable
|
Not Applicable
|
40 in
|
Foil backing for fast response
|
|
Thermocouple
|
T
|
-50 to 200°C (-58 to 392°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
40 in
|
ANSI (Standard)
|
Curved Surface Mounting
|
Curved Surface Mounting
|
Not Applicable
|
Not Applicable
|
36 in
|
Foil backing for fast response
|
|
Thermocouple
|
J
|
-50 to 200°C (-58 to 392°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
40 in
|
ANSI (Standard)
|
Flat Surface Mounting
|
Flat Surface Mounting
|
Not Applicable
|
Not Applicable
|
36 in
|
Foil backing for fast response
|
|
Thermocouple
|
K
|
-50 to 200°C (-58 to 392°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
40 in
|
ANSI (Standard)
|
Flat Surface Mounting
|
Flat Surface Mounting
|
Not Applicable
|
Not Applicable
|
40 in
|
Foil backing for fast response
|
|
Thermocouple
|
E
|
-50 to 200°C (-58 to 392°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
80 in
|
ANSI (Standard)
|
Curved Surface Mounting
|
Curved Surface Mounting
|
Not Applicable
|
Not Applicable
|
72 in
|
Foil backing for fast response
|
Wire-wound pt100 RTDs encased in a thin polyimide film with fast response times. Can be glued, epoxied, or cemented onto surfaces for temperature measurement up to 290°C.
Product Number | Category | Process Temperature Range | Sensor Application | Nominal Resistance | Accuracy | Number of Wires | Cable Insulation | Termination Connection Type | Cable Length | Mounting Style | Maximum Temperature Measurement |
---|---|---|---|---|---|---|---|---|---|---|---|
|
RTD
|
-200 to 260°C (-328 to 500°F)
|
Cement-On
|
100 Ω
|
±0.50%
|
3
|
PFA
|
Stripped Leads
|
36 in
|
DIN Platinum
|
260°C (500°F)
|
|
RTD
|
-200 to 260°C (-328 to 500°F)
|
Cement-On
|
100 Ω
|
±0.25%
|
3
|
PFA
|
Stripped Leads
|
36 in
|
DIN Platinum
|
260°C (500°F)
|
|
RTD
|
-200 to 260°C (-328 to 500°F)
|
Cement-On
|
100 Ω
|
±0.50%
|
3
|
PFA
|
Stripped Leads
|
60 in
|
DIN Platinum
|
260°C (500°F)
|
|
RTD
|
-200 to 260°C (-328 to 500°F)
|
Cement-On
|
100 Ω
|
±0.50%
|
3
|
PFA
|
Stripped Leads
|
72 in
|
DIN Platinum
|
260°C (500°F)
|
|
RTD
|
-200 to 260°C (-328 to 500°F)
|
Cement-On
|
100 Ω
|
±0.25%
|
3
|
PFA
|
Stripped Leads
|
48 in
|
DIN Platinum
|
260°C (500°F)
|
Bolt-on or bolt-mount RTD sensors encapsulated in a small stainless steel #8-32 or M4 threaded housing. Ideal for bolting to objects to measure temperatures up to 230°C.
Product Number | Category | Process Temperature Range | Sensor Application | Nominal Resistance | Accuracy | Number of Wires | Cable Insulation | Termination Connection Type | Cable Length | Additional Features | Mounting Style | Maximum Temperature Measurement | Minimum Temperature Measurement |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RTD
|
-60 to 230°C (-76 to 446°F)
|
Threaded Mounting
|
100 Ω
|
±0.15°C
|
3
|
PFA
|
3-Prong Miniature Connector
|
40 in
|
None
|
Class A DIN Platinum
|
230°C (446°F)
|
-60°C (-76°F)
|
|
RTD
|
-60 to 230°C (-76 to 446°F)
|
Threaded Mounting
|
100 Ω
|
±0.15°C
|
3
|
PFA
|
3-Prong Miniature Connector
|
40 in
|
M4 threaded tip
|
Class A DIN Platinum
|
230°C (446°F)
|
-60°C (-76°F)
|
|
RTD
|
-60 to 230°C (-76 to 446°F)
|
Threaded Mounting
|
100 Ω
|
±0.15°C
|
3
|
PFA
|
3-Prong Full-Size Connector
|
40 in
|
#8-32 threaded tip
|
Class A DIN Platinum
|
230°C (446°F)
|
-60°C (-76°F)
|
General use fast response thermistor sensors mounted in glass tape & polyimide with a self-adhesive backing for easily measuring surface temperatures up to 150°C.
Product Number | Category | Process Temperature Range | Sensor Application | Nominal Resistance | Accuracy | Cable Insulation | Termination Connection Type | Cable Length |
---|---|---|---|---|---|---|---|---|
|
Thermistor
|
-80 to 120°C (-100 to 250°F)
|
Flat or Curved Surfaces
|
2252 Ω
|
±0.2°C
|
PFA
|
Stripped Leads
|
40 in
|
|
Thermistor
|
-80 to 120°C (-100 to 250°F)
|
Flat or Curved Surfaces
|
3000 Ω
|
±0.2°C
|
PFA
|
Stripped Leads
|
40 in
|
|
Thermistor
|
-80 to 120°C (-100 to 250°F)
|
Flat or Curved Surfaces
|
10,000 Ω
|
±0.2°C
|
PFA
|
Stripped Leads
|
40 in
|
|
Thermistor
|
-80 to 120°C (-100 to 250°F)
|
Flat or Curved Surfaces
|
5000 Ω
|
±0.2°C
|
PFA
|
Stripped Leads
|
40 in
|
|
Thermistor
|
-80 to 120°C (-100 to 250°F)
|
Flat or Curved Surfaces
|
30,000 Ω
|
±0.2°C
|
PFA
|
Stripped Leads
|
40 in
|
Thermocouples with armor cable mounted inside a stainless steel washer housing. Easily bolt to a variety of surfaces to measure temperature in rugged applications.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Cable Insulation | Termination Connection Type | Cable Length | Probe Material | Probe Diameter | Color Code Standard |
---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
E
|
0 to 482°C (32 to 900°F)
|
Bolt-On
|
Fiberglass with Armored Cable
|
Stripped Leads
|
72 in
|
304 Stainless Steel
|
1/4 or M6 Screw
|
ANSI (Standard)
|
|
Thermocouple
|
J
|
0 to 482°C (32 to 900°F)
|
Bolt-On
|
Fiberglass with Armored Cable
|
Stripped Leads
|
72 in
|
304 Stainless Steel
|
1/4 or M6 Screw
|
ANSI (Standard)
|
|
Thermocouple
|
K
|
0 to 482°C (32 to 900°F)
|
Bolt-On
|
Fiberglass with Armored Cable
|
Stripped Leads
|
72 in
|
304 Stainless Steel
|
1/4 or M6 Screw
|
ANSI (Standard)
|
|
Thermocouple
|
N
|
0 to 482°C (32 to 900°F)
|
Bolt-On
|
Fiberglass with Armored Cable
|
Stripped Leads
|
72 in
|
304 Stainless Steel
|
1/4 or M6 Screw
|
ANSI (Standard)
|
|
Thermocouple
|
T
|
0 to 260°C (32 to 500°F)
|
Bolt-On
|
Fiberglass with Armored Cable
|
Stripped Leads
|
72 in
|
304 Stainless Steel
|
1/4 or M6 Screw
|
ANSI (Standard)
|
The SAP series RTD sensors come in curved and flat styles. An adhesive pad holds the sensor onto the surface to be measured. The RTD element used is Class A platimum 100 Ω.
Product Number | Category | Process Temperature Range | Sensor Application | Nominal Resistance | Accuracy | Number of Wires | Cable Insulation | Termination Connection Type | Cable Length | Additional Features | Mounting Style |
---|---|---|---|---|---|---|---|---|---|---|---|
|
RTD
|
-50 to 200°C (-58 to 392°F)
|
Self-Adhesive
|
100 Ω
|
Class A
|
4
|
PFA
|
Stripped Leads
|
3 m
|
Thin backing for fast response
|
Curved Surface Mounting
|
|
RTD
|
-50 to 200°C (-58 to 392°F)
|
Self-Adhesive
|
100 Ω
|
Class A
|
4
|
PFA
|
Stripped Leads
|
40 in
|
Thin backing for fast response
|
Curved Surface Mounting
|
|
RTD
|
-50 to 200°C (-58 to 392°F)
|
Self-Adhesive
|
100 Ω
|
Class A
|
4
|
PFA
|
Stripped Leads
|
80 in
|
Thin backing for fast response
|
Curved Surface Mounting
|
|
RTD
|
-50 to 200°C (-58 to 392°F)
|
Self-Adhesive
|
100 Ω
|
Class A
|
4
|
PFA
|
Stripped Leads
|
3 m
|
Thin backing for fast response
|
Flat Surface Mounting
|
|
RTD
|
-50 to 200°C (-58 to 392°F)
|
Self-Adhesive
|
100 Ω
|
Class A
|
4
|
PFA
|
Stripped Leads
|
40 in
|
Thin backing for fast response
|
Flat Surface Mounting
|
The RTD-831 series is designed for use as a surface sensor. It has an aluminum housing for fast transfer of heat to/from the sensing element. Choice of either 100 ohm or 1000 ohm RTD element.
Product Number | Category | Process Temperature Range | Sensor Application | Nominal Resistance | Accuracy | Number of Wires | Cable Insulation | Termination Connection Type | Cable Length | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|
|
RTD
|
-60 to 230°C (-76 to 446°F)
|
Bolt-on
|
100 Ω
|
Class “A” accuracy per IEC 60751
|
3
|
PFA
|
Stripped Ends
|
1 m
|
#3, #4 Screw Size
|
|
RTD
|
-60 to 230°C (-76 to 446°F)
|
Bolt-on
|
100 Ω
|
Class “A” accuracy per IEC 60751
|
3
|
PFA
|
Terminal Lugs
|
1 m
|
#3, #4 Screw Size
|
|
RTD
|
-60 to 230°C (-76 to 446°F)
|
Bolt-on
|
100 Ω
|
Class “A” accuracy per IEC 60751
|
3
|
PFA
|
3-Prong Miniature Connector
|
1 m
|
#3, #4 Screw Size
|
|
RTD
|
-60 to 230°C (-76 to 446°F)
|
Bolt-on
|
100 Ω
|
Class “A” accuracy per IEC 60751
|
3
|
PFA
|
3-Prong Standard Connector
|
1 m
|
#3, #4 Screw Size
|
|
RTD
|
-60 to 230°C (-76 to 446°F)
|
Bolt-on
|
100 Ω
|
Class “B” accuracy per IEC 60751
|
3
|
PFA
|
Stripped Ends
|
1 m
|
#3, #4 Screw Size
|
Spring-loaded thermocouple probes with a powerful single or dual 12lb pull magnet ideal for easily mounting to and measuring the surface temperature of ferrous metals.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Cable Insulation | Termination Connection Type | Cable Length | Color Code Standard | Mounting Style | Probe Diameter | Minimum Temperature Measurement | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
E
|
0 to 370°C (32 to 700°F)
|
Magnetic Mount Single
|
Not Applicable
|
Miniature Connector
|
40 in
|
ANSI (Standard)
|
Single Magnet Probe
|
Not Applicable
|
40 in
|
Spring Loaded thermocouple
|
|
Thermocouple
|
J
|
0 to 370°C (32 to 700°F)
|
Magnetic Mount Single
|
Stainless Steel Overbraiding
|
Miniature Connector
|
40 in
|
ANSI (Standard)
|
Single Magnet Probe
|
Not Applicable
|
40 in
|
Spring Loaded thermocouple
|
|
Thermocouple
|
K
|
0 to 370°C (32 to 700°F)
|
Magnetic Mount Single
|
Stainless Steel Overbraiding
|
Miniature Connector
|
40 in
|
ANSI (Standard)
|
Single Magnet Probe
|
Not Applicable
|
40 in
|
Spring Loaded thermocouple
|
|
Thermocouple
|
T
|
0 to 370°C (32 to 700°F)
|
Magnetic Mount Single
|
Stainless Steel Overbraiding
|
Miniature Connector with Cable Clamp
|
40 in
|
ANSI (Standard)
|
Single Magnet Probe
|
Not Applicable
|
40 in
|
Spring Loaded thermocouple
|
|
Thermocouple
|
E
|
0 to 370°C (32 to 700°F)
|
Magnetic Mount Dual
|
Stainless Steel Overbraiding
|
Miniature Connector
|
40 in
|
ANSI (Standard)
|
Dual Magnet Probe
|
Not Applicable
|
40 in
|
Spring Loaded thermocouple
|
Heat Flux thermopile sensors ideal for easily measuring heat transfer & energy efficiency of buildings, soil, pumps, R&D components, and many other thermal systems.
Product Number | Category | Thermocouple Type | Process Temperature Range | Number of Wires | Encapsulation Material | Nominal Sensitivity | Sensor Thickness | Specific Thermal Resistivity | Absolute Thermal Resistance | Heat Flux Range | Response Time | Sensing Area Dimensions | Total Sensor Dimensions | Sensing Area | Total Sensor Area |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermopile
|
T
|
-50 °C to 120 °C (-58 °F to 248 °F)
|
4
|
Kapton (polyimide)
|
14.0 mV/(W/cm2)
|
360 microns
|
0.9 K/(kW/m2)
|
1.0 K/W
|
+/- 150 kW/m2
|
0.6 seconds
|
2.5 cm x 2.5 cm
|
2.7 cm x 3.4 cm
|
6.3 cm2
|
9.2 cm2
|
|
Thermopile
|
T
|
-50 °C to 120 °C (-58 °F to 248 °F)
|
4
|
Kapton(polyimide), Copper, High Temperature Black Enamel Coating
|
70 – 90 mV/(W/cm2)
|
600 microns
|
0.9 K/(kW/m2)
|
99 K / kW
|
+/- 150 kW/m2
|
0.9 seconds
|
8.6 cm x 8.6 cm
|
9.1 cm x 10.0 cm
|
74 cm2
|
91 cm2
|
|
Thermopile
|
T
|
-20 °C to 150 °C (-4 °F to 302 °F)
|
4
|
Kapton (polyimide), Epoxy
|
1500 mv/(W/cm2)
|
1.5 mm
|
6.3 K / (kW/m2)
|
1.25 K/W
|
+/- 10 kW/m2
|
5 seconds
|
6.8 cm x 7.6 cm
|
9.2 cm x 8.7 cm
|
52 cm2
|
80 cm2
|
The ON-931 series is ideal for surface sensing. It has an aluminum housing for fast transfer of heat to the sensing element. Choice of 2252, 3000, 5000, 10,000 or 30,000 ohm thermistor element.
Product Number | Category | Process Temperature Range | Sensor Application | Nominal Resistance | Accuracy | Cable Insulation | Termination Connection Type | Cable Length |
---|---|---|---|---|---|---|---|---|
|
Thermistor
|
-80 to 100°C (-112 to 212°F)
|
Bolt-On
|
2252 Ω
|
±0.2°C
|
PFA
|
Stripped Leads
|
40 in
|
|
Thermistor
|
-80 to 100°C (-112 to 212°F)
|
Bolt-On
|
3000 Ω
|
±0.2°C
|
PFA
|
Stripped Leads
|
40 in
|
|
Thermistor
|
-80 to 100°C (-112 to 212°F)
|
Bolt-On
|
3000 Ω
|
±0.2°C
|
PFA
|
Stripped Leads
|
72 in
|
|
Thermistor
|
-80 to 100°C (-112 to 212°F)
|
Bolt-On
|
10,000 Ω
|
±0.2°C
|
PFA
|
Stripped Leads
|
40 in
|
|
Thermistor
|
-80 to 100°C (-112 to 212°F)
|
Bolt-On
|
10,000 Ω
|
±0.2°C
|
PFA
|
Stripped Leads
|
48 in
|
General use fast response RTDs mounted in glass tape & polyimide with a self-adhesive backing for easily measuring surface temperatures up to 290°C. Class B Accuracy.
Product Number | Category | Process Temperature Range | Sensor Application | Nominal Resistance | Accuracy | Number of Wires | Cable Insulation | Termination Connection Type | Cable Length | Mounting Style | Maximum Temperature Measurement | Minimum Temperature Measurement |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RTD
|
-73°C to 260°C (-100°F to 500°F)
|
Self-Adhesive
|
100 Ω
|
±0.3°C
|
3
|
PFA
|
Stripped Leads
|
40 in
|
Class B DIN Platinum
|
260°C (500°F)
|
-73°C
|
|
RTD
|
-73°C to 260°C (-100°F to 500°F)
|
Self-Adhesive
|
100 Ω
|
±0.3°C
|
4
|
PFA
|
Stripped Leads
|
40 in
|
Class B DIN Platinum
|
260°C (500°F)
|
-73°C
|
|
RTD
|
-73°C to 260°C (-100°F to 500°F)
|
Self-Adhesive
|
100 Ω
|
±0.3°C
|
3
|
PFA
|
Stripped Leads
|
80 in
|
Class B DIN Platinum
|
260°C (500°F)
|
-73°C
|
|
RTD
|
-73°C to 260°C (-100°F to 500°F)
|
Self-Adhesive
|
100 Ω
|
±0.3°C
|
3
|
PFA
|
Stripped Leads
|
120 in
|
Class B DIN Platinum
|
260°C (500°F)
|
-73°C
|
|
RTD
|
-73°C to 260°C (-100°F to 500°F)
|
Self-Adhesive
|
100 Ω
|
±0.3°C
|
3
|
PFA
|
3-Prong Miniature Connector
|
40 in
|
Class B DIN Platinum
|
260°C (500°F)
|
-73°C
|