| Product Number | Category | Thermocouple Type | Process Temperature Range | Junction Type | Nominal Resistance | Accuracy | Number of Wires | Termination Connection Type | Cable Length | Color Code Standard | Wire Gauge | Pack Size | Additional Feature 2 | 
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|  | Thermocouple | K | 0 to 593°C (32 to 1100°F) | exposed | None | None | None | Stripped Leads | 12 in | None | 44 AWG | 5 | Not applicable | 
|  | Thermocouple | K | 0 to 593°C (32 to 1100°F) | exposed | None | None | None | Stripped Leads | 12 in | None | 40 AWG | 5 | Not applicable | 
|  | Thermocouple | K | 0 to 593°C (32 to 1100°F) | exposed | None | None | None | Stripped Leads | 12 in | None | 36 AWG | 5 | Not applicable | 
|  | Thermocouple | K | 0 to 871°C (32 to 1600°F) | exposed | None | None | None | Stripped Leads | 12 in | None | 30 AWG | 5 | Not applicable | 
|  | Thermocouple | K | 0 to 871°C (32 to 1600°F) | exposed | None | None | None | Stripped Leads | 12 in | None | 26 AWG | 5 | Not applicable | 
| Product Number | Category | Thermocouple Type | Process Temperature Range | Junction Type | Nominal Resistance | Accuracy | Number of Wires | Cable Insulation | Termination Connection Type | Cable Length | Color Code Standard | Wire Gauge | Pack Size | Additional Feature 2 | 
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|  | Thermocouple | E | 0 to 482°C (32 to 900°F) | exposed | None | None | None | Fiberglass | Stripped Leads | 36 in | ANSI (standard) | 20 AWG | 5 | Not applicable | 
|  | Thermocouple | E | 0 to 482°C (32 to 900°F) | exposed | None | None | None | Fiberglass | Stripped Leads | 72 in | ANSI (standard) | 20 AWG | 5 | Not applicable | 
|  | Thermocouple | E | 0 to 426°C (32 to 800°F) | exposed | None | None | None | Fiberglass | Stripped Leads | 36 in | ANSI (standard) | 24 AWG | 5 | Not applicable | 
|  | Thermocouple | E | 0 to 426°C (32 to 800°F) | exposed | None | None | None | Fiberglass | Stripped Leads | 72 in | ANSI (standard) | 24 AWG | 5 | Not applicable | 
|  | Thermocouple | E | 0 to 315°C (32 to 600°F) | exposed | None | None | None | Fiberglass | Stripped Leads | 36 in | ANSI (standard) | 30 AWG | 5 | Not applicable | 
 
												Ready-Made Insulated Thermocouples with Kapton®, PFA, Glass Braid Insulation and Molded Connectors
| Product Number | Category | Thermocouple Type | Process Temperature Range | Junction Type | Nominal Resistance | Accuracy | Number of Wires | Cable Insulation | Termination Connection Type | Cable Length | Color Code Standard | Wire Gauge | Pack Size | 
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|  | Thermocouple | K | 0 to 482°C (32 to 900°F) | exposed | None | None | None | Fiberglass | Mini male connector with spool cap | 36 in | ANSI | 30 AWG | 1 | 
|  | Thermocouple | E | 0 to 315°C (32 to 600°F) | exposed | None | None | None | Fiberglass | Miniature Connector with Spool Cap | 36 in | ANSI (standard) | 30 AWG | 5 | 
|  | Thermocouple | E | 0 to 315°C (32 to 600°F) | exposed | None | None | None | Fiberglass | Miniature Connector with Spool Cap | 72 in | ANSI (standard) | 30 AWG | 5 | 
|  | Thermocouple | J | 0 to 482°C (32 to 900°F) | exposed | None | None | None | Fiberglass | Mini male connector with spool cap | 36 in | ANSI | 30 AWG | 5 | 
|  | Thermocouple | J | 0 to 315°C (32 to 600°F) | exposed | None | None | None | Fiberglass | Miniature Connector with Spool Cap | 72 in | ANSI (standard) | 30 AWG | 5 | 
| Product Number | Category | Thermocouple Type | Process Temperature Range | Junction Type | Nominal Resistance | Accuracy | Number of Wires | Cable Insulation | Termination Connection Type | Cable Length | Color Code Standard | Wire Gauge | Pack Size | Additional Feature 2 | 
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|  | Thermocouple | E | Not applicable | Ungrounded | None | None | None | PVC | Miniature Connector | 180 in | ANSI (standard) | 24 AWG | 1 | Not applicable | 
|  | Thermocouple | J | Not applicable | Ungrounded | None | None | None | PVC | Miniature Connector | 180 in | ANSI (standard) | 24 AWG | 1 | Not applicable | 
|  | Thermocouple | K | Not applicable | Ungrounded | None | None | None | PVC | Miniature Connector | 180 in | ANSI (standard) | 24 AWG | 1 | Not applicable | 
|  | Thermocouple | T | Not applicable | Ungrounded | None | None | None | PVC | Miniature Connector | 180 in | ANSI (standard) | 24 AWG | 1 | Not applicable | 
|  | Thermocouple | E | Not applicable | Ungrounded | None | None | None | PVC | Miniature Connector | 180 in | ANSI (standard) | 24 AWG | 5 | Not applicable | 
 
												High Temperature Inconel Overbraided Ceramic Fiber Insulated Thermocouples
| Product Number | Category | Thermocouple Type | Process Temperature Range | Junction Type | Nominal Resistance | Accuracy | Number of Wires | Cable Insulation | Termination Connection Type | Cable Length | Color Code Standard | Wire Gauge | Pack Size | Additional Feature 2 | 
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|  | Thermocouple | E | 0 to 980°C (32 to 1800°F) | exposed | None | None | None | Nextel with Inconel Braiding | Ceramic Beads With Spade lugs | 3 ft | ANSI (standard) | 20 AWG | 1 | Style 1 | 
|  | Thermocouple | E | 0 to 980°C (32 to 1800°F) | exposed | None | None | None | Nextel with Inconel Braiding | Standard Connector | 3 ft | ANSI (standard) | 20 AWG | 1 | Style 1 | 
|  | Thermocouple | E | 0 to 980°C (32 to 1800°F) | exposed | None | None | None | Nextel with Inconel Braiding | Ceramic Standard Connector | 3 ft | ANSI (standard) | 20 AWG | 1 | Style 1 | 
|  | Thermocouple | E | 0 to 980°C (32 to 1800°F) | exposed | None | None | None | Nextel with Inconel Braiding | Spade Lugs | 3 ft | ANSI (standard) | 20 AWG | 1 | Style 1 | 
|  | Thermocouple | E | 0 to 980°C (32 to 1800°F) | exposed | None | None | None | Nextel with Inconel Braiding | Stripped Leads | 3 ft | ANSI (standard) | 20 AWG | 1 | Style 1 | 
 
												Hermetically Sealed Tip Insulated Thermocouples
| Product Number | Thermocouple Type | Type of Sensor | Process Connection | Insulation | Wire Gauge | Wire Length | Termination Connection Type | Additional Feature 1 | Additional Feature 2 | Application of Sensor | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|  | T | Wire thermocouple | Direct Contact | PFA | 20 AWG (Stranded) | 65 in | Stripped Leads | Not Applicable | Easily Cleaned and Sterilized, Seal-Welded Tip | Liquid Temperature, General Purpose, Steam | ||||
|  | Thermocouple | E | 0 to 260°C (32 to 500°F) | Ungrounded | None | None | None | PFA | Stripped Leads | 36 in | ANSI (standard) | 24 AWG (Stranded) | 1 | Hermitically Seal-Welded Tip | 
|  | Thermocouple | E | 0 to 260°C (32 to 500°F) | Ungrounded | None | None | None | PFA | Stripped Leads | 72 in | ANSI (standard) | 24 AWG (Stranded) | 1 | Hermitically Seal-Welded Tip | 
|  | Thermocouple | K | 0 to 260°C (32 to 500°F) | Ungrounded | None | None | None | PFA | Stripped Leads | 1 m | ANSI (standard) | 24 AWG (Stranded) | 1 | Hermitically Seal-Welded Tip | 
|  | Thermocouple | K | 0 to 260°C (32 to 500°F) | Ungrounded | None | None | None | PFA | Stripped Leads | 36 in | ANSI (standard) | 24 AWG (Stranded) | 1 | Hermitically Seal-Welded Tip | 
 
												Thermocouple elements insulated with ceramic fiber or silica, rated up to 1200°F, available in K, E, N and J calibrations and multiple wire lengths available.
| Product Number | Application | Resistance or Output Type | Electrical Connection Type | Maximum Temperature Measurement | Minimum Temperature Measurement | Cable Length | Additional Features | Thermocouple Type | Wire Gauge | 
|---|---|---|---|---|---|---|---|---|---|
|  | Thermocouple | Not applicable | Not applicable | 980°C (1800°F) | 0°C (32°F) | 10 in | Silica insulation | Not applicable | 18 AWG | 
|  | Thermocouple | Not applicable | Not applicable | 980°C (1800°F) | 0°C (32°F) | 25 in | Silica insulation | Not applicable | 18 AWG | 
|  | Thermocouple | Not applicable | Not applicable | 980°C (1800°F) | 0°C (32°F) | 50 in | Silica insulation | Not applicable | 18 AWG | 
|  | Thermocouple | Not applicable | Not applicable | 1090°C (2000°F) | 0°C (32°F) | 3 in | Nextel Insulation | K | 14 AWG | 
|  | Thermocouple | Not applicable | Not applicable | 1090°C (2000°F) | 0°C (32°F) | 5 in | Nextel Insulation | K | 14 AWG | 
 
												High temperature ceramic insulated thermocouple wires used as-is or with protection tubes and connection heads.
| Product Number | Application | Resistance or Output Type | Probe Diameter | Mounting Style | Electrical Connection Type | Additional Features | Termination Connection Type | Thermocouple Type | Wire Gauge | Junction Type | Process Connection | Application of Sensor | Type of Sensor | 
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|  | Thermocouple | Not applicable | 4 in | Bare Wires | Stripped Leads | Not applicable | Lead Wire | K | 8 AWG | Exposed | Direct Contact/Thermowell | Air/Gas Temperature, Surface Temperature, High Temperature | Thermocouple Elements | 
|  | Thermocouple | Not applicable | 2 in | Double Hole Round Insulators | Stripped Leads | Not applicable | Lead Wire | K | 8 AWG | Exposed | Direct Contact/Thermowell | Air/Gas Temperature, Surface Temperature, High Temperature | Thermocouple Elements | 
|  | Thermocouple | Not applicable | 9 in | Double Hole Round Insulators | Stripped Leads | Not applicable | Lead Wire | K | 8 AWG | Exposed | Direct Contact/Thermowell | Air/Gas Temperature, Surface Temperature, High Temperature | Thermocouple Elements | 
|  | Thermocouple | Not applicable | 6 in | Bare Wires | Stripped Leads | Not applicable | Lead Wire | K | 14 AWG | Exposed | Direct Contact/Thermowell | Air/Gas Temperature, Surface Temperature, High Temperature | Thermocouple Elements | 
|  | Thermocouple | Not applicable | 6 in | Bare Wires | Stripped Leads | Not applicable | Lead Wire | K | 20 AWG | Exposed | Direct Contact/Thermowell | Air/Gas Temperature, Surface Temperature, High Temperature | Thermocouple Elements | 
 
												Butt-Welded Unsheathed Fine Gage Microtemp Thermocouples
| Product Number | Category | Thermocouple Type | Process Temperature Range | Junction Type | Nominal Resistance | Accuracy | Number of Wires | Termination Connection Type | Cable Length | Color Code Standard | Wire Gauge | Pack Size | Additional Feature 2 | 
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|  | Thermocouple | K | 0 to 593°C (32 to 1100°F) | exposed | None | None | None | Stripped Leads | 12 in | None | 40 AWG | 5 | Butt Welded | 
|  | Thermocouple | K | 0 to 593°C (32 to 1100°F) | exposed | None | None | None | Stripped Leads | 12 in | None | 36 AWG | 5 | Butt Welded | 
|  | Thermocouple | K | 0 to 871°C (32 to 1600°F) | exposed | None | None | None | Stripped Leads | 12 in | None | 30 AWG | 5 | Butt Welded | 
|  | Thermocouple | K | 0 to 871°C (32 to 1600°F) | exposed | None | None | None | Stripped Leads | 12 in | None | 26 AWG | 5 | Butt Welded | 
|  | Thermocouple | K | 0 to 871°C (32 to 1600°F) | exposed | None | None | None | Stripped Leads | 12 in | None | 24 AWG | 5 | Butt Welded | 
| Product Number | Category | Thermocouple Type | Process Temperature Range | Junction Type | Nominal Resistance | Accuracy | Number of Wires | Cable Insulation | Termination Connection Type | Cable Length | Color Code Standard | Wire Gauge | Pack Size | Additional Feature 2 | 
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|  | RTD | None | -60 to 250°C (-76 to 482°F) | None | 100 Ω | Class A per IEC60751 | 3 | PFA | Stripped Leads | 5 m | IEC | 26 AWG | 1 | None | 
|  | RTD | None | -60 to 250°C (-76 to 482°F) | None | 100 Ω | Class A per IEC60751 | 4 | PFA | Stripped Leads | 1 m | IEC | 26 AWG | 1 | None | 
|  | RTD | None | -60 to 250°C (-76 to 482°F) | None | 100 Ω | Class A per IEC60751 | 4 | PFA | Stripped Leads | 2 m | IEC | 26 AWG | 1 | None | 
|  | RTD | None | -60 to 250°C (-76 to 482°F) | None | 100 Ω | Class A per IEC60751 | 4 | PFA | Stripped Leads | 3 m | IEC | 26 AWG | 1 | None | 
|  | RTD | None | -60 to 250°C (-76 to 482°F) | None | 100 Ω | Class A per IEC60751 | 4 | PFA | Stripped Leads | 4 m | IEC | 26 AWG | 1 | None | 
 
												Can be used for surface measurements or as part of a larger assembly. These sensors are comprised of a thermistor, cable and insulated connections.
| Product Number | Application | Resistance or Output Type | Temperature Accuracy | Electrical Connection Type | Cable Length | Additional Features | Housing Material | 
|---|---|---|---|---|---|---|---|
|  | Thermistor | 2252 Ω @ 25°C | ±0.2°C @ 0 to 70°C | Stripped Leads | 36 in | Standard | PFA | 
|  | Thermistor | 2252 Ω @ 25°C | ±0.2°C @ 0 to 70°C | Stripped Leads | 40 in | Standard | PFA | 
|  | Thermistor | 2252 Ω @ 25°C | ±0.2°C @ 0 to 70°C | Stripped Leads | 80 in | Standard | PFA | 
|  | Thermistor | 3000 Ω @ 25°C | ±0.2°C @ 0 to 70°C | Stripped Leads | 36 in | Standard | PFA | 
|  | Thermistor | 3000 Ω @ 25°C | ±0.2°C @ 0 to 70°C | Stripped Leads | 40 in | Standard | PFA | 
 
												STYLE 3 RTD ELEMENT, 4 WIRES W/CONN FOR HH804
| Product Number | Application | Resistance or Output Type | Temperature Accuracy | Number of Wires | Probe Diameter | Probe Diameter | Maximum Temperature Measurement | Minimum Temperature Measurement | Cable Length | Additional Features | Termination Connection Type | 
|---|---|---|---|---|---|---|---|---|---|---|---|
|  | RTD elements - Wire Wound with extension wires | 100 Ω | Class A per IEC60751 | 4 | Not Applicable | 2mm L x 2mm W | 260°C (500°F) | -30°C (-22°F) | 8 in | Standard | Stripped Wires | 
|  | RTD elements - Wire Wound with extension wires | 100 Ω | Class A per IEC60751 | 2 | Not Applicable | 2mm L x 2mm W | 300°C (572°F) | -30°C (-22°F) | 1 m | Fiberglass Insulated Wires | Stripped Wires | 
|  | RTD elements - Wire Wound with extension wires | 100 Ω | Class A per IEC60751 | 2 | Not Applicable | 2mm L x 2mm W | 260°C (500°F) | -30°C (-22°F) | 1 m | PFA Insulated Wires | Stripped Wires | 
|  | RTD elements - Wire Wound with extension wires | 100 Ω | Class A per IEC60751 | 2 | Not Applicable | 2mm L x 2mm W | 450°C (842°F) | -100°C (-148°F) | 20 in | Standard | Stripped Wires | 
|  | RTD elements - Wire Wound with extension wires | 100 Ω | Class A per IEC60751 | 2 | Not Applicable | 2mm L x 2mm W | 260°C (500°F) | -30°C (-22°F) | 31 in | Standard | Stripped Wires | 
| Product Number | Application | Resistance or Output Type | Temperature Accuracy | Number of Wires | Mounting Style | Maximum Temperature Measurement | Cable Length | Additional Features | Termination Connection Type | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|  | Fast Response Sensors | 100 Ω | ±0.15°C @ 0°C | 2 | Class A DIN Platinum | 480°C (900°F) | 36 in | Not applicable | Stripped Wires | ||||||||||||||
|  | RTD | 100 Ω | Class B per IEC60751 | 3 | Stripped Leads | 300°C (572°F) | -30°C (-22°F) | 36 in | Fiberglass | none | ANSI (standard) | Stripped Leads | 1 | Fiberglass | 36 in | 26 AWG | None | None | RTD | 100 Ω | Class B per IEC60751 | 3 | -30 to 299°C (-22 to 570°F) | 
|  | RTD | 100 Ω | Class B per IEC60751 | 3 | Stripped Leads | 260°C (500°F) | -30°C (-22°F) | 36 in | PFA | none | ANSI (standard) | Stripped Leads | 1 | PFA | 26 AWG | 36 in | None | None | RTD | 100 Ω | -30 to 260°C (-22 to 500°F) | Class B per IEC60751 | 3 | 
|  | Fast Response Sensors | 100 Ω | ±0.15°C @ 0°C | 4 | Class A DIN Platinum | 230°C (450°F) | 36 in | Not applicable | Stripped Wires | ||||||||||||||
|  | Fast Response Sensors | 100 Ω | ±0.15°C @ 0°C | 4 | Class A DIN Platinum | 480°C (900°F) | 36 in | Not applicable | Stripped Wires | ||||||||||||||
 
												Unsheathed Fine Gage Tungsten-Rhenium Microtemp Thermocouples
| Product Number | Category | Thermocouple Type | Process Temperature Range | Junction Type | Nominal Resistance | Accuracy | Number of Wires | Cable Insulation | Termination Connection Type | Cable Length | Color Code Standard | Wire Gauge | Pack Size | Additional Feature 2 | 
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|  | Thermocouple | D | 0 to 105°C (32 to 221°F) | exposed | None | None | None | None | Stripped Leads | 12 in | None | 40 AWG | 1 | Not applicable | 
|  | Thermocouple | D | 0 to 105°C (32 to 221°F) | exposed | None | None | None | None | Stripped Leads | 12 in | None | 36 AWG | 1 | Not applicable | 
|  | Thermocouple | D | Not applicable | exposed | None | None | None | None | Stripped Leads | 60 in | None | 36 AWG | 1 | Not applicable | 
|  | Thermocouple | D | Not applicable | exposed | None | None | None | None | Stripped Leads | 24 in | None | 30 AWG | 1 | Not applicable | 
|  | Thermocouple | D | 0 to 105°C (32 to 221°F) | exposed | None | None | None | None | Stripped Leads | 16 in | None | 26 AWG | 1 | Not applicable | 
| Product Number | Application | Resistance or Output Type | Temperature Accuracy | Number of Wires | Mounting Style | Maximum Temperature Measurement | Cable Length | Additional Features | Termination Connection Type | 
|---|---|---|---|---|---|---|---|---|---|
|  | Fast Response Sensors | 100 Ω | ±0.15°C @ 0°C | 3 | Class A DIN Platinum | 480°C (900°F) | 96 in | Not applicable | Stripped Leads | 
|  | Fast Response Sensors | 100 Ω | ±0.15°C @ 0°C | 2 | Class A DIN Platinum with 1PT100K620 Element | 230°C (450°F) | 36 in | Not applicable | Stripped Leads | 
|  | Fast Response Sensors | 100 Ω | ±0.15°C @ 0°C | 2 | Class A DIN Platinum | 600°C (1112°F) | 1 m | Not applicable | Stripped Leads | 
|  | Fast Response Sensors | 100 Ω | ±0.15°C @ 0°C | 2 | Class A DIN Platinum | 480°C (900°F) | 1 m | Not applicable | Stripped Leads | 
|  | Fast Response Sensors | 100 Ω | ±0.15°C @ 0°C | 2 | Class A DIN Platinum | 230°C (450°F) | 1 m | Not applicable | Stripped Leads | 
| Product Number | Application | Resistance or Output Type | Temperature Accuracy | Number of Wires | Mounting Style | Maximum Temperature Measurement | Cable Length | Additional Features | Termination Connection Type | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|  | Fast Response Sensors | 100 Ω | ±0.15°C @ 0°C | 2 | Class A DIN Platinum | 480°C (900°F) | 20 in | F3101 Element | Stripped Leads | ||||||||||||||
|  | Fast Response Sensors | 100 Ω | ±0.15°C @ 0°C | 2 | Class A DIN Platinum | 480°C (900°F) | 1 m | Standard | Stripped Leads | ||||||||||||||
|  | Fast Response Sensors | 100 Ω | ±0.15°C @ 0°C | 2 | Class A DIN Platinum | 230°C (450°F) | 1 m | Standard | Stripped Leads | ||||||||||||||
|  | Fast Response Sensors | 100 Ω | ±0.15°C @ 0°C | 2 | Class A DIN Platinum | 480°C (900°F) | 20 in | Standard | Stripped Leads | ||||||||||||||
|  | RTD | 100 Ω | Class A per IEC60751 | 2 | Stripped Leads | 300°C (572°F) | -30°C (-22°F) | 36 in | None | none | ANSI (standard) | Stripped Leads | 1 | 36 in | 26 AWG | None | None | RTD | 100 Ω | None | Class A per IEC60751 | -30 to 300°C (-22 to 572°F) | 2 | 
 
												Unsheathed Fine Gage Tungsten-Rhenium Microtemp Thermocouples
| Product Number | Category | Thermocouple Type | Process Temperature Range | Junction Type | Nominal Resistance | Accuracy | Number of Wires | Termination Connection Type | Cable Length | Color Code Standard | Wire Gauge | Pack Size | Additional Feature 2 | 
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|  | Thermocouple | D | 0 to 2325°C (32 to 4200°F) | exposed | None | None | None | Stripped Leads | 12 in | None | 30 AWG | 1 | Not applicable | 
|  | Thermocouple | D | 0 to 2325°C (32 to 4200°F) | exposed | None | None | None | Stripped Leads | 36 in | None | 30 AWG | 1 | Not applicable | 
|  | Thermocouple | D | 0 to 2325°C (32 to 4200°F) | exposed | None | None | None | Stripped Leads | 12 in | None | 26 AWG | 1 | Not applicable | 
|  | Thermocouple | D | 0 to 2325°C (32 to 4200°F) | exposed | None | None | None | Stripped Leads | 12 in | None | 24 AWG | 1 | Not applicable | 
|  | Thermocouple | D | 0 to 2325°C (32 to 4200°F) | exposed | None | None | None | Stripped Leads | 18 in | None | 24 AWG | 1 | Not applicable | 
| Product Number | Category | Thermocouple Type | Process Temperature Range | Junction Type | Nominal Resistance | Accuracy | Number of Wires | Cable Insulation | Termination Connection Type | Cable Length | Color Code Standard | Wire Gauge | Pack Size | Additional Feature 2 | 
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|  | Thermistor | None | 0 to 100°C (32 to 212°F) | None | 2252 Ω | ±0.2°C | 2 | PVC | Stripped Leads | 12 in | None | 22 AWG | 1 | Vinyl Tipped | 
|  | Thermistor | None | 0 to 100°C (32 to 212°F) | None | 3000 Ω | ±0.2°C | 2 | PVC | Stripped Leads | 12 in | None | 22 AWG | 1 | Vinyl Tipped | 
|  | Thermistor | None | 0 to 100°C (32 to 212°F) | None | 10000 Ω | ±0.2°C | 2 | PVC | Stripped Leads | 12 in | None | 22 AWG | 1 | Vinyl Tipped | 
|  | Thermistor | None | 0 to 100°C (32 to 212°F) | None | 5000 Ω | ±0.2°C | 2 | PVC | Stripped Leads | 12 in | None | 22 AWG | 1 | Vinyl Tipped | 
|  | Thermistor | None | 0 to 100°C (32 to 212°F) | None | 3000 Ω | ±0.1°C | 2 | PVC | Stripped Leads | 12 in | None | 22 AWG | 1 | Vinyl Tipped | 